Geelongs minimum expectations:

  • If using BESS 50 percent and a pass in the compulsory categories (Water Energy stormwater and Internal Environmental Quality (IEQ)).

Energy Performance

  • Minimum 50% score in BESS Energy category
  • Cooling loads to not exceed 30MJ/sqm for any dwelling
  • Minimum 6.5 star NatHERS average

IEQ

  • Appropriate orientation and daylight access

Water Resources

  • Rainwater capture and reuse for toilet flushing at a minimum
  • Minimum 50% score in BESS Water Category

Stormwater management

  • 100 percent STORM score or MUSIC modelling demonstrating best practice stormwater management

Transport

  • Bicycle parking - 1 per dwelling

Waste management

  • Recycling facilities are at least as convenient to future occupants as general waste facilities.